UDKG-01A |
UDKG-PRO |
Measurement range of gamma radiation DER |
0,1 – 5000 µSv/h |
0,1 – 9999 µSv/h |
Main relative permissible error limit of gamma radiation DER measurement with confidence probability of 0.95 (calibrated relative to 137Cs) |
25+2/Н*(10)%, where H*(10) is a numeric value of the measured DER in µSv/h |
15+2/Н*(10)%, where H*(10) is a numeric value of the measured DER in µSv/h |
Measurement range of gamma radiation DE |
0,001 – 9999 mSv |
0,001 – 9999 mSv |
Main relative permissible error limit of gamma radiation DE measurement with confidence probability of 0.95 |
25% |
15% |
Energy range of registered gamma radiation |
0,05 – 3,00 MeV |
0,05 – 3,00 MeV |
Energy dependence of the detector readings at gamma radiation DER and DE measurements in the energy range from 0.05 MeV to 1.25 MeV |
25% |
25% |
Range of the Bluetooth interface for connection with the smartphone/tablet, not less than |
5 m |
5 m |
Battery life (ENERGIZER AAA×2 of 1280 mAh capacity) under natural background radiation conditions, not less than |
60 hours |
60 hours |
General operating supply voltage of the detector from two AAA batteries |
3,0 V |
3,0 V |
Dimensions, not more than |
19х40х95 mm |
19х40х95 mm |
Weight without batteries, not more than |
0,05 kg |
0,05 kg |